Skip to content
NewCybercrime Report 2026 · Eight Chapters · A Post Is Not An Incident → Explore The ChaptersCybercrime Report 2026 → Explore

Citrix Bleed 2 (CVE-2025-5777)

CVE-2025-5777 is a flaw in NetScaler ADC and NetScaler Gateway where weak input checking lets the device read and return memory it should not.

Reviewed by
Brandefense Analyst Team
Published
Reading Time
2 min read
CVE ID
CVE-2025-5777
Vendor
Cloud Software Group (NetScaler, formerly Citrix)
Affected Product
NetScaler ADC and NetScaler Gateway
Exploitation
Listed in CISA KEV
Published
June 2025

It is widely called Citrix Bleed 2. CISA lists it as exploited and flags known ransomware campaign use.

What it allows

An outsider with no account can make the appliance return memory it should keep private. The vendor rates it 9.3 out of 10 on the CVSS v4 scale and asks customers to end active sessions after upgrading, so treat open sessions as untrusted.

Who is affected

Per the vendor, only when the appliance is set up as a Gateway (VPN, ICA Proxy, CVPN, RDP Proxy) or as an AAA virtual server. Affected: 14.1 before 14.1-43.56, 13.1 before 13.1-58.32, 13.1-FIPS and NDcPP before 13.1-37.235, and 12.1-FIPS before 12.1-55.328. Versions 12.1 and 13.0 are end of life and vulnerable. Secure Private Access deployments using NetScaler are also affected. The bulletin covers customer-managed products only.

The vendor published its bulletin on 17 June 2025, together with a second flaw, CVE-2025-5349. CISA added CVE-2025-5777 to its Known Exploited Vulnerabilities (KEV) catalog on 10 July 2025. The KEV entry flags known use in ransomware campaigns.

The vendor also published a guide to checking logs for signs of attempted exploitation. The sources opened here do not name which groups used the flaw.

What to do

  1. Upgrade to a fixed build

    The vendor names 14.1-43.56, 13.1-58.32, 13.1-FIPS and NDcPP 13.1-37.235 and 12.1-FIPS 12.1-55.328, or later. Replace end-of-life 12.1 and 13.0 appliances.

  2. End active sessions after upgrading

    Once every appliance in the HA pair or cluster runs a fixed build, the vendor says to run kill icaconnection -all and kill pcoipConnection -all.

  3. Check Secure Private Access

    The vendor says NetScaler instances behind Secure Private Access on-prem or hybrid setups must be upgraded too.

  4. Review logs for attempts

    Use the vendor's guide on evaluating NetScaler logs for signs of attempted exploitation.

What Brandefense can do

Frequently Asked Questions

What is Citrix Bleed 2 (CVE-2025-5777)?

Citrix Bleed 2 is the common name for CVE-2025-5777, a flaw in NetScaler ADC and NetScaler Gateway where weak input checking lets the device return memory it should keep private. An outsider with no account can trigger it.

Which NetScaler setups are affected by CVE-2025-5777?

Per the vendor, only appliances set up as a Gateway (VPN, ICA Proxy, CVPN, RDP Proxy) or as an AAA virtual server. Versions 12.1 and 13.0 are end of life and vulnerable.

How do I fix CVE-2025-5777?

Upgrade to 14.1-43.56, 13.1-58.32, 13.1-FIPS and NDcPP 13.1-37.235, or 12.1-FIPS 12.1-55.328, or later. Then end active sessions with kill icaconnection -all and kill pcoipConnection -all, as the vendor says.

Is CVE-2025-5777 exploited?

CISA added it to its Known Exploited Vulnerabilities catalog on 10 July 2025, and the entry flags known ransomware campaign use. The sources opened for this page do not name which groups used the flaw.

Sources

  1. NetScaler ADC and NetScaler Gateway Security Bulletin for CVE-2025-5349 and CVE-2025-5777Cloud Software Group
  2. CVE-2025-5777 recordNIST NVD
  3. Known Exploited Vulnerabilities catalogCISA
ShareLinkedInX
Brandefense logo

Stay Ahead of Digital Threats.

Take control of your digital security with an exclusive demo of our AI-driven threat intelligence platform.

Open The Full Demo Form →