Adobe says a low-privileged attacker could execute arbitrary code in the context of the current user without user interaction. The issue carries a critical CVSS 3.1 score of 9.9.Adobe published bulletin APSB26-162 on 27 October 2026. Its advisory identifies affected builds and a fixed build, but does not disclose the specific authorization check or an exploit procedure. The distinction matters when assessing exposure: this profile describes the stated access conditions and outcome, not a tested attack path.
What it allows
How Does CVE-2026-105780 Affect Adobe Campaign Classic?
Adobe classifies the flaw as incorrect authorization. Its CVE record says a low-privileged attacker could reach the issue over a network and execute code as the current user. No victim action is required, and Adobe's CVSS vector marks the scope as changed.
One defensive reading is a chain from access to an affected ACC server, through an authorization boundary, to code execution. That is our interpretation of Adobe's stated conditions, not a disclosed exploit sequence. Adobe does not identify an endpoint, an exact permission, or the code path involved.
In Brandefense Blackhole, the 23 August to 21 November 2026 search counted one dark-chat post mentioning CVE-2026-105780. The measured unit is a post mentioning the CVE, not an affected server or a verified attack. This discussion signal does not establish exploitation.
For prioritization, compare deployed builds with Adobe's affected and current release lists. The related Brandefense product is the Vulnerability Intelligence platform. Adobe's same bulletin also covers a separate ACC SQL injection flaw, CVE-2026-105489. Treat the identifiers as separate findings while coordinating one ACC update.
Who is affected
Which ACC Builds Are Affected by CVE-2026-105780?
Adobe lists Adobe Campaign Classic ACC v7 7.4.4 build 9402 and earlier as affected on Windows and Linux. Its solution table names ACC v7 7.4.4 build 9403 as the updated build for both platforms. Adobe's 18 November 2026 release notes now mark 9403 deprecated and list 7.4.4 build 9404 and 7.4.5 build 9421 as GA.
The notes say Adobe-hosted instances have been remediated, while on-premise and hybrid deployments need customer updates. The Adobe CNA record also marks build 9403 unaffected.
Inventory each running ACC instance and record its complete version and build number. Compare that value with Adobe's bulletin before changing the installation. A patch management process should retain the running build after the update, because a package download alone does not prove the service has loaded the current GA build.
Timeline
-
2026-10-27
Adobe published APSB26-162 and the CVE-2026-105780 record, naming the affected and updated ACC v7 builds.
-
2026-11-20
The CISA KEV catalog snapshot used for this profile did not list CVE-2026-105780.
What to do
-
Identify ACC v7 installations
Record the installed version, build, platform and service owner for every ACC server. Prioritize 7.4.4 build 9402 and earlier on Windows and Linux.
-
Apply Adobe's ACC update
Follow Adobe bulletin APSB26-162 and current release notes to choose a supported ACC v7 build. Adobe lists 7.4.4 build 9404 and 7.4.5 build 9421 as GA; build 9403 is deprecated.
-
Verify the running build
After updating, restart the Adobe Campaign server (nlserver) as the release notes require. Open Help > About in the client console and verify the application server version and build match the installed GA release. Retain the build evidence in the change record.
-
Review access during the patch window
Review access to affected ACC servers and investigate unusual low-privilege account activity. This is defensive triage guidance, not a vendor detection signature for this CVE.
What Brandefense can do
- Watch your stack for exploited flaws
Name the vendors and products you run, and Brandefense alerts you when a CVE in them is exploited.
- See CVE-2026-105780 in Brandefense Atlas
The Atlas record of CVE-2026-105780: severity, exploitation status and the sources behind it.
- Vulnerability intelligence platform
Brandefense Vulnerability Intelligence follows which vulnerabilities attackers are using, so your team can patch what is under attack first.
Frequently Asked Questions
Does CVE-2026-105780 require an administrator account?
No. Adobe says a low-privileged attacker could exploit the flaw, and its CVSS vector requires low privileges rather than administrator privileges.
What version fixes CVE-2026-105780?
APSB26-162 names ACC v7 7.4.4 build 9403 as its updated version. Adobe's 18 November release notes mark 9403 deprecated and list 7.4.4 build 9404 and 7.4.5 build 9421 as GA. Check the current release and verify the running application server build.
Does exploitation require a user to click anything?
Adobe's CVE record says exploitation does not require user interaction. Its CVSS 3.1 vector also records UI:N.
Has Adobe reported attacks using this flaw?
Adobe's 27 October 2026 bulletin says it was not aware of exploits in the wild for the issues it addressed. That statement does not prove later exploitation cannot occur.
Sources
- Adobe Security Bulletin APSB26-162Adobe
- Adobe Campaign Classic v7 Latest ReleaseAdobe
- Launching Adobe CampaignAdobe
- CVE-2026-105780 RecordAdobe CNA via CVE Program
- Known Exploited Vulnerabilities CatalogCISA