Citrix says it can cause unpredictable or erroneous behavior, or a denial of service. The flaw applies when an ADC has a Load Balancing or Content Switching virtual server of type SMPP.Citrix first published the security bulletin on 12 November 2026 and revised its page on 20 November. Its bulletin covers many separate CVEs, so the SMPP configuration condition matters for this record. The public description does not identify the exact memory operation or document an attack against a specific deployment.
What it allows
How Does CVE-2026-107407 Affect SMPP Traffic?
The route described by Citrix begins with SMPP traffic reaching an affected ADC virtual server. The vulnerable memory handling may then disrupt the appliance's behavior or service availability. This is our high-level reading of Citrix's description, not a published exploit procedure or an incident report.
Citrix scores this CVE as remotely reachable without authentication or user interaction. Its stated precondition still limits this flaw to ADC deployments with an SMPP Load Balancing or Content Switching virtual server. A NetScaler Gateway deployment alone is not the precondition for this CVE.
Citrix's advisory identifies the SMPP configuration and branch-specific fixed builds as the basis for action on affected ADCs.
For a broader risk queue, see the vulnerability intelligence platform. The NetScaler packet-processing CVE-2026-120868 profile covers a separate flaw with different prerequisites.
Who is affected
Which NetScaler Builds Are Affected?
Citrix lists customer-managed NetScaler ADC 14.1 builds before 14.1-73.57 and 13.1 builds before 13.1-64.39. Its bulletin also lists ADC 14.1 FIPS before 14.1-73.58 FIPS. For ADC 13.1 FIPS and 13.1 NDcPP, the threshold is 13.1-37.293.
For this CVE, each affected ADC also needs an SMPP Load Balancing or Content Switching virtual server. Citrix tells customers to inspect the configuration for an LB or CS virtual server of type SMPP. Secure Private Access Hybrid deployments using customer-managed NetScaler instances also need the recommended builds.
The bulletin applies to customer-managed appliances; Citrix says it updates its managed cloud services and managed Adaptive Authentication. Check both the running build and the SMPP server type before assigning this CVE to an appliance. Record the appliance edition as well, because standard, FIPS and NDcPP builds have different fixed thresholds.
This is a concrete vulnerability prioritization decision: document which exposed ADC instances need the first maintenance window. Compare the running release with Citrix's branch-specific fixed build, then verify the build again after the upgrade.
Timeline
- 2026-11-12
Citrix initially published security bulletin CTX697305, including CVE-2026-107407.
- 2026-11-13
NVD published its CVE-2026-107407 record.
- 2026-11-20
Citrix's bulletin page shows its latest modification date; CISA's 20 November KEV catalog did not list this CVE.
What to do
-
Identify SMPP virtual servers
Inspect each customer-managed NetScaler ADC configuration for LB or CS virtual servers of type SMPP, as Citrix instructs. Record the instance, edition and running build.
-
Install the branch-specific fixed build
Upgrade affected standard 14.1 appliances to 14.1-73.57 or later, and standard 13.1 appliances to 13.1-64.39 or later. Use 14.1-73.58 FIPS or later for 14.1 FIPS, and 13.1-37.293 or later for 13.1 FIPS and NDcPP.
-
Confirm the running build after upgrade
After the appliance restarts, verify its actual running build and edition against Citrix's fixed-version list. Repeat this check for every SMPP LB or CS virtual server host.
-
Review service health and relevant logs
Check service availability and appliance logs for unexplained errors or restarts around SMPP traffic. This is general defensive triage, not a CVE-specific detection signature.
What Brandefense can do
- Watch your stack for exploited flaws
Name the vendors and products you run, and Brandefense alerts you when a CVE in them is exploited.
- See CVE-2026-107407 in Brandefense Atlas
The Atlas record of CVE-2026-107407: severity, exploitation status and the sources behind it.
- Vulnerability intelligence platform
Brandefense Vulnerability Intelligence follows which vulnerabilities attackers are using, so your team can patch what is under attack first.
Frequently Asked Questions
Does every NetScaler ADC have this SMPP flaw?
Citrix limits CVE-2026-107407 to ADC configurations with an SMPP Load Balancing or Content Switching virtual server. Check the running build and that specific server type.
What is the fixed build for NetScaler ADC 14.1?
Citrix names 14.1-73.57 or later for standard ADC 14.1. The separate 14.1 FIPS line starts at 14.1-73.58 FIPS.
Does the CVSS score prove data theft or code execution?
No. Citrix describes unpredictable behavior or denial of service, while its CVSS 4.0 vector scores potential confidentiality and integrity impact.
Is CVE-2026-107407 in CISA's KEV catalog?
It was not listed in CISA's catalog version 2026.11.20, checked on 21 November 2026. Treat KEV status as time-sensitive.