Citrix says the flaw can cause unpredictable or erroneous behavior, or denial of service. Citrix rates it 9.3 Critical under CVSS 4.0; neither its bulletin nor the initial NVD record provides a CVSS 3.1 score.This CVE applies when an appliance has an Email Action configured. Check that condition before prioritizing an appliance as exposed. Teams can record the configuration and corrected build in a vulnerability intelligence platform to keep remediation tied to the affected deployment.
What it allows
How Does CVE-2026-107415 Affect Email OTP?
Citrix identifies a memory overflow in the Email OTP authentication path. An appliance with an Email Action meets the stated configuration precondition. Citrix describes possible unpredictable behavior or denial of service, but does not provide a complete attack chain or confirm code execution for this CVE.
The Citrix CVSS 4.0 vector describes a network attack requiring no prior privileges or user interaction. A score describes potential impact, not observed exploitation. CVE-2026-111340 is a separate knowledge-based authentication flaw; Citrix says an Email Action can also satisfy that CVE's precondition.
What Is Known About Exploitation?
Exploitation status is unknown in this profile. The available CISA KEV catalog snapshot is dated November 10, 2026, before Citrix disclosed this CVE on November 12. Its absence from that snapshot cannot establish the status after disclosure.
Prioritize exposed appliances by checking the Email Action setting and installed build. Review appliance availability and authentication-service errors around the affected deployment. Use the existing incident response process to investigate anomalies. These checks follow from Citrix's stated precondition and possible denial-of-service impact.
Who is affected
Which Builds and Configurations Are Affected?
Citrix says a NetScaler ADC or NetScaler Gateway needs an Email Action configured for CVE-2026-107415. Inspect each customer-managed appliance's authentication configuration for an Email Action, then identify its running build. An Email Action also appears in Citrix's separate CVE-2026-111340 KBA preconditions; assess that CVE independently.
The bulletin lists NetScaler ADC and Gateway 14.1 builds before 14.1-73.57 and 13.1 builds before 13.1-64.39. For NetScaler ADC 14.1-FIPS, the threshold is 14.1-73.58 FIPS. For ADC 13.1-FIPS and 13.1-NDcPP, the threshold is 13.1-37.293.
Citrix says Secure Private Access Hybrid deployments using NetScaler instances also need relevant updates. The bulletin applies to customer-managed appliances; Cloud Software Group updates Citrix-managed cloud services and Adaptive Authentication. Keep a branch-specific patch management record for each instance.
Timeline
-
2026-11-12
Citrix initially published bulletin CTX697305 with the Email Action precondition and corrected NetScaler builds.
-
2026-11-13
NVD published its initial CVE-2026-107415 record.
What to do
-
Check the Email Action precondition
Inspect authentication configuration on customer-managed NetScaler ADC and Gateway appliances. Record whether an Email Action exists and match each appliance to its running build.
-
Install the corrected build
Update affected 14.1 appliances to 14.1-73.57 or later and 13.1 appliances to 13.1-64.39 or later. Use 14.1-73.58 FIPS or later for ADC 14.1-FIPS, and 13.1-37.293 or later for ADC 13.1-FIPS and 13.1-NDcPP.
-
Verify the running version
After installation, check the build actually running on each appliance. Compare it with Citrix's fixed threshold for that exact branch and record the result.
-
Review appliance health
Review authentication-service errors, unexpected restarts, and availability for affected appliances. Investigate anomalies through the incident response process without assuming this CVE caused them.
What Brandefense can do
- Watch your stack for exploited flaws
Name the vendors and products you run, and Brandefense alerts you when a CVE in them is exploited.
- See CVE-2026-107415 in Brandefense Atlas
The Atlas record of CVE-2026-107415: severity, exploitation status and the sources behind it.
- Vulnerability intelligence platform
Brandefense Vulnerability Intelligence follows which vulnerabilities attackers are using, so your team can patch what is under attack first.
Frequently Asked Questions
Does CVE-2026-107415 affect every NetScaler installation?
Citrix specifies an Email Action as the precondition. Check the authentication configuration and running build before deciding whether an appliance is exposed.
Is CVE-2026-107415 the same flaw as CVE-2026-111340?
No. Citrix describes CVE-2026-107415 as an Email OTP heap-based overflow. It lists CVE-2026-111340 separately as a knowledge-based authentication stack overflow.
Which NetScaler versions fix CVE-2026-107415?
Citrix lists 14.1-73.57, 13.1-64.39, 14.1-73.58 FIPS, and 13.1-37.293 for the relevant FIPS or NDcPP branch. Verify the running build after updating.