Dell says an attacker with internal network access could execute arbitrary commands as root on the NAS node. Dell assigns CVSS 3.1 9.8 Critical. Internal reachability is the stated condition; the advisory does not describe an internet attack path or a confirmed incident.The Dell advisory also lists CVE-2026-116448 with the same short description. It is a separate identifier. The PowerStore TFTP overflow profile covers another distinct SDNAS flaw in the same advisory.
What it allows
How Can CVE-2026-116449 Affect a NAS Node?
Dell classifies the defect as OS command injection, or CWE-78. Its stated outcome is arbitrary command execution as root on the NAS node. The vendor does not identify the vulnerable function, protocol, input route or complete attack sequence. That limits any more specific claim about how an attacker would reach it.
Dell describes an attacker with internal network access. Its CVSS vector records network access, no required privileges and no user interaction. The useful defensive question is which systems can reach the affected NAS node from inside the environment. Put that finding beside the running version in the Vulnerability Intelligence platform workflow.
Is There Evidence of Active Exploitation?
Brandefense Blackhole counted two dark-chat posts matching CVE-2026-116449 from 20 August through 18 November 2026. The unit is posts, not attacks or affected organizations. Discussion does not establish exploitation. The checked CISA KEV catalog version 2026.11.18 did not list this CVE.
For local investigation, review NAS node administrative activity and changes near suspected access. Compare the timing with internal network connection records where available. These are defensive review steps, not Dell-published indicators specific to this CVE. An unusual record alone cannot prove this flaw was used.
Who is affected
Which PowerStore Models and Versions Need Review?
Dell's 5.1.x remediation table lists these PowerStore models for CVE-2026-116449. For these rows, versions before 5.1.0.0-2798105 are affected, and Dell names 5.1.0.0-2798105 or later as the remedy.
- 500T
- 1000T
- 1200T
- 3000T
- 3200Q
- 3200T
- 5000T
- 5200Q
- 5200T
- 7000T
- 9000T
- 9200T
- 1500
- 5500
- 9500
PowerStore 9500 appears in both Dell's CVE record and its 5.1.x advisory row. The row names 5.1.0.0-2798105 or later as the remedy for this CVE.
Dell's 4.3.x LTS rows name 4.3.1.3-2800620, but their addressed-CVE lists omit CVE-2026-116449. Dell says 4.3.x fixes are arriving across multiple patches. Therefore, the listed 4.3.x build is not documented here as a fix for this CVE. Record the installed branch and build, and obtain Dell's branch-specific guidance for any 4.3.x deployment.
Timeline
- 2026-10-30
Dell issued DSA-2026-479, according to its revision history.
- 2026-11-17
Dell revised the advisory to add 4.3.x LTS remediation rows. Those rows do not list CVE-2026-116449 among their addressed CVEs.
- 2026-11-18
Dell published the CVE-2026-116449 record through the CVE Program.
What to do
-
Inventory the affected NAS estate
Record each PowerStore model, PowerStoreT OS branch, installed build and internal network access path. Separate 5.1.x systems from 4.3.x LTS systems.
-
Update listed 5.1.x models
For Dell's 5.1.x rows that name this CVE, apply 5.1.0.0-2798105 or a later Dell-supported release. Prioritize reachable NAS nodes.
-
Verify the running release
After maintenance, read the running build on each updated system. Compare it with Dell's model-specific row and retain the before and after versions.
-
Resolve the 4.3.x scope
Ask Dell whether and when this CVE is addressed on 4.3.x LTS. Do not infer coverage from another CVE's patch row.
What Brandefense can do
- Watch your stack for exploited flaws
Name the vendors and products you run, and Brandefense alerts you when a CVE in them is exploited.
- See CVE-2026-116449 in Brandefense Atlas
The Atlas record of CVE-2026-116449: severity, exploitation status and the sources behind it.
- Vulnerability intelligence platform
Brandefense Vulnerability Intelligence follows which vulnerabilities attackers are using, so your team can patch what is under attack first.
Frequently Asked Questions
Does CVE-2026-116449 require internet exposure?
Dell specifies an attacker with internal network access. Its advisory does not claim that internet exposure is required.
Which 5.1.x build addresses CVE-2026-116449?
Dell lists 5.1.0.0-2798105 or later for its 5.1.x rows that name this CVE. Verify the running build and model.
Does PowerStoreT OS 4.3.1.3 fix this CVE?
Dell's 4.3.x rows list that build but omit CVE-2026-116449 from the addressed CVEs. Confirm the applicable fix with Dell.
Is CVE-2026-116449 the same as CVE-2026-116448?
No. Dell assigns separate CVE identifiers, although its advisory gives them the same short impact description.