Skip to content
NewCybercrime Report 2026 · Eight Chapters · A Post Is Not An Incident → Explore The ChaptersCybercrime Report 2026 → Explore

XOneManager Project Data Authorization Bypass (CVE-2026-124770)

CVE-2026-124770 is an authorization bypass in XOneManager 3.8.3.0.

Reviewed by
Brandefense Analyst Team
Published
Reading Time
3 min read
CVE ID
CVE-2026-124770
Vendor
XOne
Affected Product
XOneManager
Exploitation
No exploitation reported
Published
2026-11-20

INCIBE says an authenticated project member can cause database queries to run without the server checking that member's execution permissions.The queries use the service account's permissions, rather than the member's project permissions. During testing, researchers queried databases outside the project, including the authentication database. Those test results show the potential reach of the flaw; they do not describe an observed intrusion.

What it allows

How Does CVE-2026-124770 Cross the Project Boundary?

INCIBE identifies the affected operation as tablesData. The server accepts a request from an authenticated project member but does not check whether that member may execute the requested query. The service account then supplies broader database permissions.

INCIBE reports that its testing reached databases outside the member's project, including the authentication database. This is an authorization failure after login, not evidence that an anonymous visitor can trigger it. The exact data available depends on the service account's database permissions and the deployed configuration.

INCIBE's 20 November 2026 table labels exploitation for this CVE as “No.” The CISA KEV catalog released on 20 November 2026 does not list the identifier. Neither statement proves what has happened on any individual installation.

Brandefense Blackhole counted two dark-chat posts mentioning CVE-2026-124770 from 24 August through 22 November 2026. The measured unit is a post mentioning the identifier, not a compromised system or confirmed attack. Discussion alone cannot establish exploitation.

Use Vulnerability Intelligence to organize the affected XOneManager inventory and response priority. The vulnerability prioritization glossary explains how access conditions and asset importance affect that decision.

Who is affected

Which XOneManager Version Needs the Fix?

INCIBE and the CVE record explicitly identify XOneManager 3.8.3.0 as affected. The published description requires an authenticated project member. It does not state that every earlier release is affected or provide a comparable range for other branches.

INCIBE says XOne fixed the six related vulnerabilities in XOneManager 4.0.7.6. The server now verifies a user's role and permissions for API operations. Install 4.0.7.6 or a later vendor release, then verify the version running on each server.

If the installed build is not the named affected or fixed build, consult XOne's release information before classifying it. Record the installed and running versions in the patch management workflow. A version string alone cannot confirm that a particular user's project permissions were reviewed.

What to do

  1. Inventory XOneManager servers and project access

    Find XOneManager installations, record their running versions, and identify members who can access projects. Prioritize servers on 3.8.3.0 with valuable databases linked to projects.

  2. Update to the fixed release

    Follow XOne's upgrade guidance and install XOneManager 4.0.7.6 or later. Coordinate with database and application owners before changing production systems.

  3. Verify the running release and roles

    Confirm each upgraded server reports 4.0.7.6 or later after restart. Review project membership and database service account privileges against the intended access policy.

  4. Review existing database access records

    Examine available service account query and database access records for unexpected access beyond project scope. Treat unusual activity as a triage lead, not proof of this CVE.

What Brandefense can do

Frequently Asked Questions

Does CVE-2026-124770 require a login?

Yes. INCIBE describes an authenticated project member using an operation that lacks the required execution-permission check.

Which XOneManager release fixes this issue?

INCIBE says XOneManager 4.0.7.6 fixes the related vulnerabilities and recommends updating to that version or later. Verify the running version after upgrading.

Was access outside a project demonstrated?

INCIBE says testing queried databases outside the project, including the authentication database. This is a test finding, not a report of an intrusion at a customer installation.

Sources

  1. Multiple Vulnerabilities in XOne's XOneManagerINCIBE-CERT
  2. CVE-2026-124770 recordCVE Program
  3. CVE-2026-124770 vulnerability detailNIST NVD
  4. Known Exploited Vulnerabilities CatalogCISA
ShareLinkedInX
Brandefense logo

Stay Ahead of Digital Threats.

Take control of your digital security with an exclusive demo of our AI-driven threat intelligence platform.

Open The Full Demo Form →