Splunk says an unauthenticated user could view RapidDiag process metadata and a log file inventory. A factory-default shared key accepted for node authentication lets affected requests bypass Splunk user authentication.The flaw concerns information disclosure, not a stated ability to run searches or change data. Splunk classifies it as use of hard-coded credentials (CWE-798). The vendor tracks the issue as VULN-112484 in its 18 November 2026 advisory.
What it allows
How Does CVE-2026-131190 Bypass Splunk Authentication?
Splunk says certain RapidDiag REST API requests accept a factory-default key for node authentication. A requester without a Splunk user session can thereby reach process metadata and the inventory of log files. The disclosure concerns what files and processes exist; Splunk does not describe access to the log contents under this CVE.
This is distinct from CVE-2026-76535, the RapidDiag task-collection flaw. Splunk says that other issue can run SPL searches as an authenticated user. Keep the exposure and response checks for the two CVEs separate, even though the same advisory covers them.
Brandefense Blackhole counted one dark-chat post mentioning CVE-2026-131190 between 24 August and 22 November 2026. The measured unit is a post, not an incident or a unique actor. This mention alone does not establish exploitation.
Our defensive reading is to identify instances where the RapidDiag app is present and review access to the management service. Examine relevant authentication and RapidDiag activity for unexpected requests. These are triage steps inferred from the vendor's description, not a published detection signature.
CISA's catalog dated 20 November 2026 did not list this CVE in KEV. Catalog status does not settle whether anyone has exploited it. For the wider release context, see the Splunk November fixes overview.
Who is affected
Version Check
| Release Line | Affected Range | Fixed In |
|---|---|---|
| 9.4.x | 9.4.0 to before 9.4.17 | 9.4.17 |
| 10.0.x | 10.0.0 to before 10.0.12 | 10.0.12 |
| 10.2.x | 10.2.0 to before 10.2.9 | 10.2.9 |
| 10.4.x | 10.4.0 to before 10.4.5 | 10.4.5 |
For distribution packages and custom builds, check the supplier’s advisory.
The CVE-specific description does not name the 10.6 branch; verify it separately with Splunk.
Which Splunk Enterprise Versions Need the CVE-2026-131190 Fix?
Splunk's CVE-specific description names the 10.4, 10.2, 10.0 and 9.4 branches. Its Product Status table identifies affected releases as 10.4.0 through 10.4.4, 10.2.0 through 10.2.8, 10.0.0 through 10.0.11 and 9.4.0 through 9.4.16. The corresponding fixes are 10.4.5, 10.2.9, 10.0.12 and 9.4.17.
The advisory's general Product Status table also lists a 10.6 fix for the wider vulnerability bundle. Splunk does not name the 10.6 branch in this CVE's own description. Confirm branch-specific applicability with Splunk before treating that general row as a CVE-2026-131190 claim.
Record each instance's running version and whether RapidDiag is installed and active. Prioritize affected instances whose management service can be reached by untrusted networks. Use the patch management process to track the actual post-upgrade version. See the Vulnerability Intelligence product page for related product information.
Splunk's stated workaround is to turn off or remove the RapidDiag app. Treat that as an interim control while moving affected branches to fixed releases. Verify the app's state after the change and confirm the running Splunk Enterprise version after the upgrade.
Timeline
-
2026-11-18
Splunk published SVD-2026-1103, including CVE-2026-131190 and its fixed versions.
-
2026-11-19
NVD published the CVE-2026-131190 record.
What to do
-
Inventory affected Splunk Enterprise instances
Record the installed branch and running version. Check whether RapidDiag is present and whether the management service is reachable from untrusted networks.
-
Apply the branch-specific fix
Upgrade affected 10.4, 10.2, 10.0 and 9.4 branches to 10.4.5, 10.2.9, 10.0.12 and 9.4.17 or later within each branch, respectively.
-
Verify the running release
After the change, confirm each instance reports the intended fixed version. Keep the observed release and change record together.
-
Use the vendor workaround where needed
If an upgrade must wait, turn off or remove the RapidDiag app as Splunk advises. Verify its state and review unexpected management-service activity.
What Brandefense can do
- Watch your stack for exploited flaws
Name the vendors and products you run, and Brandefense alerts you when a CVE in them is exploited.
- See CVE-2026-131190 in Brandefense Atlas
The Atlas record of CVE-2026-131190: severity, exploitation status and the sources behind it.
- Vulnerability intelligence platform
Brandefense Vulnerability Intelligence follows which vulnerabilities attackers are using, so your team can patch what is under attack first.
Frequently Asked Questions
Does CVE-2026-131190 require a Splunk login?
No. Splunk says an unauthenticated requester can reach RapidDiag process metadata and the log file inventory because affected requests accept a factory-default shared key.
Can this CVE expose log contents or run SPL searches?
Splunk describes process metadata and a log file inventory for this CVE. It does not describe log-content access or search execution under this identifier.
What is the temporary workaround?
Splunk advises turning off or removing the RapidDiag app. Upgrade affected branches to their fixed releases and verify the running version afterward.