Skip to content
NewCybercrime Report 2026 · Eight Chapters · A Post Is Not An Incident → Explore The ChaptersCybercrime Report 2026 → Explore

Budibase Cross-Tenant Attachment Key Bypass (CVE-2026-137494)

CVE-2026-137494 is a broken object-level authorization flaw in Budibase @budibase/server before 4.0.0.

Reviewed by
Brandefense Analyst Team
Published
Reading Time
3 min read
CVE ID
CVE-2026-137494
Vendor
Budibase
Affected Product
@budibase/server
Exploitation
Not confirmed
Published
2026-11-26

An authenticated user with write access to a table can make an attachment reference point to a file in another app or tenant. The vendor-hosted advisory describes cross-tenant deletion and conditional reading through the shared APPS object-store bucket.Budibase lists 4.0.0 as patched, and the CVE Program marks that release unaffected. The advisory describes a static-analysis finding and an attack path; it does not establish that a real-world intrusion occurred.

What it allows

How Does CVE-2026-137494 Cross the Tenant Boundary?

Budibase's advisory says the server saves a client-supplied attachment key without binding it to the current app. Its key sanitization blocks path traversal segments but does not enforce an app prefix. Subsequent attachment handling uses that stored key in the shared APPS bucket.

A user who can write to a table could reference another app's attachment key in a row. Updating or deleting that row can delete the referenced object. Reading the specific attachment requires knowing its key, including a random filename component, so the advisory treats deletion as the more practical risk.

For teams applying vulnerability intelligence, the immediate decision is which deployments share an object store across apps or tenants. Treat the advisory's public proof of concept as a description of a possible path, not evidence of an intrusion. The separate Budibase MongoDB query bypass profile concerns a different authorization flaw.

What Does the Evidence Say About Exploitation?

The advisory says its analysis was static, and the CVE Program record describes the same possible attack path. Neither source identifies an observed intrusion. The CISA KEV snapshot dated 25 November 2026 did not list this CVE; that snapshot predates the CVE Program publication.

Brandefense Blackhole recorded 1 dark-chat post matching CVE-2026-137494 from 29 August to 27 November 2026. This is a count of matching posts, not a count of incidents or successful exploitation. We recommend reviewing object-store access and deletion logs for cross-app attachment operations; that investigation step is our inference from the advisory's described data flow.

Who is affected

Which Budibase Versions Are Affected?

The CVE Program lists Budibase @budibase/server versions before 4.0.0 as affected and 4.0.0 as unaffected. The vendor-hosted advisory gives the same upper boundary and lists 4.0.0 as patched. Its described prerequisite is an authenticated user with table write access and a reachable attachment key belonging to another app.

Check the version running on each deployment, including private and self-hosted instances. Compare the deployed server package or release with 4.0.0, then verify the update completed on every instance. An attack surface inventory can help locate overlooked deployments.

Timeline

  1. 2026-11-10

    Vendor-hosted GitHub advisory published and listed 4.0.0 as patched.

  2. 2026-11-10

    Budibase v4.0.0 release published.

  3. 2026-11-26

    VulnCheck published CVE-2026-137494 in the CVE Program.

What to do

  1. Upgrade Budibase

    Update affected @budibase/server deployments to Budibase 4.0.0 or a later supported release. Follow the vendor's release guidance for the installed distribution.

  2. Verify the running version

    After the update, confirm that every running Budibase server reports 4.0.0 or later. Record the observed version for each separately managed environment.

  3. Review attachment activity

    Review application and object-store logs for unexpected attachment deletion or access across app boundaries. This is a defensive check inferred from the advisory's attack path.

  4. Restore and investigate affected files

    If suspicious cross-app deletion is found, preserve relevant logs and restore affected objects from a trusted backup. Assess whether attachment keys or file contents were exposed before returning the app to normal use.

What Brandefense can do

Frequently Asked Questions

What is CVE-2026-137494?

It is a Budibase attachment-key authorization flaw. A user with table write access can reference another app's file and may delete it or conditionally read it.

Which Budibase version fixes the flaw?

Budibase lists 4.0.0 as patched. The CVE Program marks @budibase/server 4.0.0 as unaffected and earlier versions as affected.

Can the flaw expose any attachment?

The advisory says reading a specific attachment requires knowing its key, including a random filename component. It describes deletion through known keys as the more practical path.

Does the advisory confirm attacks in the wild?

The advisory describes static analysis and a possible attack path. It does not identify a confirmed intrusion.

Sources

  1. Budibase Cross-Tenant Attachment Key AdvisoryBudibase repository via GitHub Security Advisories
  2. CVE-2026-137494 RecordVulnCheck CNA via CVE Program
  3. Budibase v4.0.0 ReleaseBudibase
  4. Known Exploited Vulnerabilities CatalogCISA
ShareLinkedInX
Brandefense logo

Stay Ahead of Digital Threats.

Take control of your digital security with an exclusive demo of our AI-driven threat intelligence platform.

Open The Full Demo Form →