Article
Exposed PLCs: lessons from the 2026 US advisory
US agencies say Iranian-affiliated actors disrupted exposed PLCs. See the attack flow and what water, energy and public facility operators should check.
Quick links
Press Enter to search, Esc to close
Significant cyber incident
US agencies say Iranian-affiliated actors have been disrupting internet-exposed industrial controllers (PLCs) in US government, water and energy organizations since at least March 2026.
In short
US agencies say Iranian-affiliated actors have been disrupting internet-exposed industrial controllers (PLCs) in US government, water and energy organizations since at least March 2026. The advisory was published on 7 April 2026 and widened on 22 July 2026 to cover Rockwell, Schneider Electric and Siemens devices. The actors took copies of project files and changed logic and operator screens, in some cases disabling shutdown and alarm logic.
On 7 April 2026 US agencies, led by the FBI and CISA, published advisory AA26-097A. It warned of Iranian-affiliated actors disrupting internet-connected controllers (PLCs) in several US critical infrastructure sectors. The agencies say the activity goes back to at least March 2026.
On 22 July 2026 the advisory was updated. It added Schneider Electric and Siemens controllers to the Rockwell Automation devices first covered, and added guidance on spotting changed code modules. The agencies say this is not a new product flaw. It is opportunistic targeting of exposed, poorly protected devices.
On 30 July 2026 CISA issued a separate alert for the water sector. It describes a significant rise in attacks on exposed PLCs, with lockouts and boil water notices. That alert does not name an actor.
Earlier campaign: IRGC-affiliated actors begin accessing US water facilities using Unitronics PLCs (advisory AA23-335A)
Earliest date the advisory gives for actor association with one listed IP address group
Agencies identify, through victim engagements, an Iranian-affiliated group disrupting PLCs
CISA, FBI, NSA, EPA, DOE, CNMF and Treasury publish advisory AA26-097A
Advisory lists further actor IP addresses first associated in this period
Advisory lists more actor IP addresses first associated this month
AA26-097A updated: Schneider Electric and Siemens added, new guidance on Rockwell code modules, exfiltration of project files described
CISA alert urges water and wastewater operators to remove exposed PLCs; boil water notices reported
The actors used foreign-based IP addresses to reach internet-facing PLCs from Rockwell Automation, Schneider Electric and Siemens. They used leased, third-party hosted servers and the makers’ own programming software to connect to misconfigured devices. Internet Accessible Device (T0883) is the access method the advisory lists. The advisory says this is not a new product vulnerability.
Traffic targeted ports 44818, 2222, 102 and 502, which are common industrial protocol ports. The advisory lists this as Commonly Used Port (T0885). It also saw traffic aimed at modems on port 22. In one case the actors put Dropbear SSH software on victim modems for remote access, listed as Remote Access Tools (T1219).
The actors used configuration software (Studio 5000 Logix Designer, EcoStruxure Control Expert and TIA Portal) on leased infrastructure to move device project files out to their own servers. The advisory lists this as Exfiltration Over C2 Channel (T1041).
After taking the files, the actors modified and deleted project logic, including Add-On Instructions, and altered data on HMI and SCADA displays. This is listed as Data Manipulation (T1565). At one victim the FBI saw a malicious project file that kept normal ladder logic but overrode instructions that keep operating conditions safe. The changes disabled shutdown and alarm logic, so systems could enter unsafe conditions without telling operators.
CISA’s 30 July alert describes actors changing passwords to lock out operators and changing PLC IP addresses to disconnect them. It does not say these actors are the same as those in AA26-097A.
Attributed by the FBI, CISA, NSA, EPA, DOE, US Cyber Command CNMF and Treasury, 7 April 2026 (updated 22 July 2026), to "a group of Iranian-affiliated APT actors".
The advisory says the agencies previously reported on similar PLC activity by CyberAv3ngers (aka Shahid Kaveh Group), affiliated with the IRGC Cyber Electronic Command. It does not say the 2026 group is CyberAv3ngers.
CISA's water sector alert of 30 July 2026 names no actor and no country. This page does not treat it as the same actor.
Organizations in several US critical infrastructure sectors (government services and facilities, water and wastewater, energy) had controllers disrupted. Some victims had operational disruption and financial loss. Victims are not named and no figures are given.
At one victim, changes disabled shutdown and alarm logic so systems could enter unsafe conditions without alerting operators.
CISA's separate 30 July 2026 water alert says exposed PLC targeting has resulted in boil water notices and sustained manual operations. It does not say how many systems or which actor.
The advisory says this is opportunistic targeting of exposed, poorly protected PLCs, not a new product flaw. Taking controllers off the internet removes the main route in.
Actors targeted cellular modems, and CISA says some may be undocumented and missed by routine scans. Keep a full list of remote connections.
Actors took project files and then changed logic. Compare running logic with known good copies and check reusable code modules.
Changes disabled shutdown and alarm logic so operators were not told. Alarm and safety logic needs change control and monitoring.
CISA advises a known clean PLC backup in case of lockout, and says to check restored backups for malicious logic.
CISA's water alert names no actor. Treat each government source on its own terms.
List every PLC, HMI and modem reachable from the internet, including cellular modems added by vendors or integrators that may be undocumented.
Search logs for the IP addresses in AA26-097A and for traffic on ports 44818, 2222, 102, 502 and 22, especially from foreign hosting providers. Vet the addresses before blocking.
Route remote access through a gateway or VPN with MFA, and allowlist known engineering laptops only.
Compare running logic with known good logic, check Add-On Instructions or reusable modules, and confirm shutdown and alarm logic is intact.
Put physical mode switches in run position where they exist, and replace default or empty passwords.
Keep tested offline backups of PLC logic and configuration, and check them for malicious logic before restoring.
Threat intelligence monitoring could flag risk early by watching for new government advisories and indicator lists for your PLC brands, exposed credentials and remote-access details tied to your organization, and named actor activity in your sector. It cannot replace removing exposure, but it can tell you sooner that your devices are being scanned or targeted.
US agencies attribute them to a group of Iranian-affiliated APT actors (advisory AA26-097A). The advisory references CyberAv3ngers as earlier similar activity but does not say it is the same group.
Potentially all internet-exposed PLCs. Named targets include Rockwell Automation CompactLogix and Micro850, Schneider Electric Modicon M340 and Siemens S7-1200.
The advisory says it is not highlighting a new vulnerability. It describes opportunistic targeting of exposed, misconfigured devices.
The alert does not name an actor or link itself to AA26-097A. It reports lockouts, IP changes and boil water notices at water systems.
Remove PLCs from direct internet exposure, check logs for the advisory's indicators and ports, and review project files for unauthorized changes.
Take control of your digital security with an exclusive demo of our AI-driven threat intelligence platform.