Dell PowerStore SDNAS Command Injection (CVE-2026-116448)

CVE-2026-116448 is an OS command injection flaw in Dell PowerStore SDNAS.

Reviewed by
Brandefense Analyst Team
Published
Reading Time
3 min read
CVE ID
CVE-2026-116448
Vendor
Dell
Affected Product
PowerStore SDNAS
Exploitation
Not confirmed
Published
2026-11-18

Dell says an attacker with internal network access could run arbitrary commands as root on the NAS node. The advisory assigns a CVSS 3.1 score of 9.8, Critical.Dell lists this CVE for PowerStoreT OS 5.1.x builds before 5.1.0.0-2798105 on specified PowerStore models. Its 4.3.x remediation rows cover other CVEs, but do not list CVE-2026-116448. Teams should match the appliance model and running build to the CVE-specific row before scheduling the update.

What it allows

How Could CVE-2026-116448 Affect a NAS Node?

Dell identifies OS command injection in PowerStore SDNAS. In the described attack path, a person with access to the internal network reaches the vulnerable NAS function, and commands run as root on the NAS node. Dell does not identify the exact interface or input handling mistake in this advisory, so the path cannot be narrowed further from this source.

Root command execution could let an attacker alter data or disrupt the NAS node, consistent with Dell’s high confidentiality, integrity, and availability impact scores. That is potential impact, not evidence of an incident. CVE-2026-116449 appears separately in the same advisory with a similar description; CVE-2026-116446 instead concerns an NFS out-of-bounds memory flaw.

Our triage starts with PowerStore appliances whose NAS access is reachable from internal segments. Use the vulnerability intelligence platform to organize the advisory, then confirm model and build on each appliance. The PowerStore SDNAS TFTP overflow profile covers a different flaw in the same advisory.

What Is Known About Exploitation?

The CISA KEV catalog snapshot dated 17 November 2026 does not list CVE-2026-116448. That dated catalog status does not establish whether a particular deployment has been targeted. Dell describes possible exploitation and does not report a specific incident in the advisory.

Who is affected

Which PowerStore Models and Builds Are Listed?

Dell lists PowerStore 500T, 1000T, 1200T, 3000T, 3200Q, 3200T, 5000T, 5200Q, 5200T, 7000T, 9000T, 9200T, 1500, 5500, and 9500 with PowerStoreT OS 5.1.x before 5.1.0.0-2798105 for CVE-2026-116448. It lists 5.1.0.0-2798105 or later as remediated for those model rows. Confirm both the model and full running build, including the build suffix, before deciding whether the advisory applies.

The advisory also contains PowerStoreT OS 4.3.x LTS rows with a separate fix threshold of 4.3.1.3-2800620. Those rows omit CVE-2026-116448. Do not use the 4.3.x threshold as the fix for this CVE; ask Dell to clarify any deployment whose branch or model does not match a listed CVE-specific row.

How Should Teams Patch and Verify?

For a listed, affected 5.1.x appliance, plan the Dell PowerStoreT OS update to 5.1.0.0-2798105 or later. Prioritize systems where untrusted internal users can reach NAS services. Follow the patch management process to coordinate service impact and a post-update check.

After maintenance, read the running OS build from each appliance and confirm it is at least 5.1.0.0-2798105 within the 5.1.x branch. Recheck the intended internal network paths to NAS services. As a defensive investigation step, compare NAS administrative activity and appliance logs with expected changes; unusual activity alone is not proof of this CVE.

Timeline

  1. 2026-10-30

    Dell records the initial release of advisory DSA-2026-479.

  2. 2026-11-17

    Dell updates the advisory with 4.3.x LTS remediation rows for other listed CVEs. CVE-2026-116448 is absent from those rows.

  3. 2026-11-18

    NVD publishes the CVE-2026-116448 record and reproduces Dell’s SDNAS command injection description.

What to do

  1. Identify listed appliances

    Record each PowerStore model, active PowerStoreT OS branch, and full running build. For this CVE, compare the model against Dell’s 5.1.x rows.

  2. Prioritize internal NAS exposure

    Map which internal segments can reach NAS services on listed appliances. Review access paths while scheduling the vendor update.

  3. Install the Dell fix

    Update listed, affected 5.1.x appliances to PowerStoreT OS 5.1.0.0-2798105 or later, following Dell’s advisory and maintenance guidance.

  4. Verify the running version

    After maintenance, confirm that each updated appliance reports a 5.1.x build of 5.1.0.0-2798105 or later. Review NAS logs and authorized administrative changes for anomalies.

What Brandefense can do

Frequently Asked Questions

Does CVE-2026-116448 require internet exposure?

Dell describes an attacker with internal network access. Its CVSS vector uses network attack vector, but the advisory does not identify the exact reachable interface.

Which PowerStoreT OS build fixes CVE-2026-116448?

Dell lists 5.1.0.0-2798105 or later as remediated for the specified PowerStore models running 5.1.x. Verify the full active build after updating.

Does Dell list the 4.3.x LTS fix for this CVE?

The advisory’s 4.3.x LTS rows list other CVEs but omit CVE-2026-116448. The 4.3.1.3-2800620 threshold should not be treated as this CVE’s fix.

Are CVE-2026-116448 and CVE-2026-116449 the same record?

No. Dell assigns two separate CVE identifiers, even though the advisory gives them the same SDNAS command injection impact description.

Sources

  1. DSA-2026-479: Dell PowerStore T Security Update for Multiple VulnerabilitiesDell
  2. CVE-2026-116448 DetailNVD
  3. Known Exploited Vulnerabilities CatalogCISA
ShareLinkedInX
Brandefense logo

Stay Ahead of Digital Threats.

Take control of your digital security with an exclusive demo of our AI-driven threat intelligence platform.

Open The Full Demo Form →