An attacker positioned between machines could relay a legitimate user's NTLM authentication to impersonate that user.Siemens says the resulting impact depends on accessible services and may include code execution with the user's privileges. Track the advisory's changing remediation status through a vulnerability intelligence platform.
What it allows
How Can CVE-2026-58114 Affect a SCADA System?
The root cause is insufficient protection of remote user authentication using the deprecated NTLM protocol. Siemens says an unauthenticated attacker must first obtain a machine-in-the-middle position, then relay NTLM authentication to impersonate a legitimate user.
The attack also requires user interaction according to Siemens' CVSS vectors. Accessible services, such as a WinCC SQL server, determine what an impersonated session can reach. Siemens says code execution with the victim user's privileges is possible, depending on service access.
Brandefense Blackhole counted two dark-chat posts matching CVE-2026-58114 from August 19 through November 17, 2026. The measured unit is matching posts, which do not establish an incident or active exploitation.
For the broader method of ranking such conditional exposure, see our vulnerability intelligence explainer. The November 13 CISA KEV catalog did not list this CVE when Brandefense checked it on November 17.
Who is affected
Which SIMATIC Products and Versions Are Affected?
Siemens lists all versions of SIMATIC BATCH V9.1 and SIMATIC PCS 7 V9.1. All versions of SIMATIC Information Server 2020 and 2022, plus SIMATIC Process Historian 2020 and 2022, are also affected.
All versions of SIMATIC WinCC V7.5, V8.0, and V8.1 are affected. The same applies to SIMATIC WinCC Runtime Professional V17, V18, V19, V20, and V21.
As of the November 10 advisory, Siemens planned no fix for BATCH, Information Server, PCS 7, or Process Historian. It said no fix was yet available for the listed WinCC and WinCC Runtime Professional versions.
On each host, read the installed Siemens product release and build from its local software inventory or version display. Compare that release with the affected-product rows in SSA-970803. Record NTLM use and SQL service access separately to assess impact.
After any later product-specific fix, repeat the running-build check and confirm service connectivity. The separate SIMATIC IoT2050 CVE-2026-58115 profile covers a different product and flaw.
Timeline
- 2026-11-10
Siemens published SSA-970803, version 1.0, with affected products and mitigations.
- 2026-11-17
Brandefense reviewed Siemens' advisory and the CISA KEV catalog version dated November 13; this CVE was not listed in that catalog.
What to do
-
Inventory the affected systems
Identify the listed WinCC, Runtime Professional, PCS 7, BATCH, Information Server, and Process Historian releases. Record which systems use NTLM and which services they can access.
-
Encrypt SQL Server communication
Apply Siemens' specific mitigation for manually configuring encrypted SQL Server Database communication. Follow the linked Siemens product instructions and validate the resulting connection in a maintenance window.
-
Restrict network paths
Follow Siemens' recommendation to protect device network access and its industrial security operational guidelines. Brandefense recommends limiting authentication and SQL traffic to trusted segments and monitoring unexpected paths.
-
Review NTLM dependence
Siemens notes that Kerberos needs a domain with an SPN and says users must assess risk when Kerberos is not used. Brandefense recommends reviewing NTLM use before any authentication change.
-
Verify remediation status after vendor updates
Recheck SSA-970803 for each installed product before scheduling maintenance. If Siemens later releases a fix, apply the appropriate build and verify the running version and service connectivity afterward.
What Brandefense can do
- Watch your stack for exploited flaws
Name the vendors and products you run, and Brandefense alerts you when a CVE in them is exploited.
- See CVE-2026-58114 in Brandefense Atlas
The Atlas record of CVE-2026-58114: severity, exploitation status and the sources behind it.
- Vulnerability intelligence platform
Brandefense Vulnerability Intelligence follows which vulnerabilities attackers are using, so your team can patch what is under attack first.
Frequently Asked Questions
What is CVE-2026-58114?
It is a weak authentication flaw in several Siemens SIMATIC SCADA and PCS 7 products. An on-path attacker may relay NTLM authentication and impersonate a legitimate user.
Does CVE-2026-58114 allow unauthenticated remote code execution?
Siemens requires a machine-in-the-middle position and its CVSS vectors require user interaction. Code execution is a possible outcome with the victim user's privileges, depending on accessible services.
Which Siemens versions need attention?
Siemens lists all versions of 14 specified product releases across BATCH, Information Server, PCS 7, Process Historian, WinCC, and WinCC Runtime Professional.
Is a Siemens fix available for CVE-2026-58114?
The November 10 advisory says no fix is planned for BATCH, Information Server, PCS 7, and Process Historian. No fix was then available for the listed WinCC products.